Capital Planning
Mailing Address
Cleveland State University
2121 Euclid Avenue, PS 235
Cleveland, OH 44115-2214
Campus Location
Plant Services Building
1802 East 25th Street, PS 235
Phone: 216-687-2500
Construction Updates
Construction Update
Construction activities and events that could impact mobility on campus this week: Physical Education Building – Roof Replacement & Exterior Masonry Wall Restoration
Location Impacted: Exterior of Physical Education Building and surrounding vicinity.
Construction started on June 13, 2013 on the roof replacement and masonry wall restoration project at the Physical Education Building. Work is anticipated to be complete by November 17,
2013. The scope of the project consists of the removal and replacement of the existing roof
system for the entire building.
IMPORTANT CONSTRUCTION UPDATE
On Friday 9-6-2013 a temporary, partial closure of the drive on the East side of the PE building (between PE and Mather Mansion) will occur. The closure is anticipated to start at 6:30 am and be complete by 2:00 pm. Traffic will be maintained.
Rhodes Tower/ Main Classroom Plaza Deck Waterproofing and Concrete Repair
Location Impacted: Exterior south, east and west sides of Rhodes Tower and west side of Main Classroom Plaza Level (1st Floor) and Lower Level. The scope of the project will consist of concrete repairs to the walking surfaces, structural concrete repairs to the plaza structures, waterproofing, stone repair and railing replacement. Work is anticipated to be complete by December 21, 2013
IMPORTANT CONSTRUCTION UPDATE
Work will continue on the plaza and temporary closures of the connections to the Student
Center plaza may occur as construction proceeds.
Lower Level access will be maintained as it currently is for the duration of construction.
Temporary partial lane closures will continue at 21st and 22nd street for the next few months.
Please follow posted alternative routes and avoid walking in the street along 21st & 22nd. Pedestrian access to the buildings will be maintained at all times, however some doors and or
pedestrian routes will be closed from time to time depending on construction activities. Detours and alternative routes will be posted, and notifications will be sent out in advance.
For further details, please go to our website at www.csuohio.edu/offices/architect/
CHESTER AVE.
CHESTER AVE.
HIGHLIGHTED AREAS ARE CURRENTLY
CLOSED FOR CONSTRUCTION
SOUTHERLY R/W
OPEN
INDICATES THAT DOOR OR WALKWAY IS CURRENTLY OPEN DURING CONSTRUCTION
LINE OF BUILDING ABOVE
LINE OF BUILDING ABOVE
21
21 22
36
21
36
10 RHODES TOWER (RT) 36
LOWER LEVEL
RHODES WEST (RW)
PLAZA LEVEL (1st FLOOR)
RHODES TOWER- LIBRARY (RT)
PLAZA LEVEL (1st FLOOR)
21
STAGING
AREA #3 11
OPEN 5' - 0" X X
CLEAR
CENTRAL GARAGE (CG)
LOWER LEVEL
6
X X X
1
10
6
X X X 12 10
18
2
CENTRAL GARAGE (CG)
UPPER LEVEL
15 34
34
RHODES TOWER
23
23
13 24
34 8' - 0" CLEAR
RHODES 15
PLAZA
2
22
14
LINE OF PLAZA ABOVE
STAGING AREA #2
X X X X 5 5
16
16
1 8
8
EXIT ONLY
11 X X X
21
OPEN
33
32
OPEN
11 30 31
31 29
11 10
11
OPEN TO BELOW
25
29 31
11
30
34 OPEN TO
BELOW 29
X X X X
26
OPEN TO BELOW
13
OPEN
21
OPEN
X X X X X X X X X
10
EXIT 3
X X X X X
STL PIPE 4 14
RAISED R.R. TIE
11 10
12" WIDE
CONC. WALL
2' WIDE CONC. WALL
OPEN OP11EN
28
3' WIDE
ENTRY ONLY
18
19 ONLY
12
20
10
2
11
CROSSHATCHED AREA
INDICATES APPROXIMATE WORK
OLPIMEITSN
VISITOR PARKING (LOT 22 PayStation)
BOLLARD
OPEN
(DELIVERIES ONLY) 10
9
STAGIING AREA #1
MAIN CLASSROOM (MC) UPPER LEVEL PARKING (MG)
PLANTERS
32
CROSSHATCHED AREA INDICATES APPROXIMATE WORK LIMITS
CONC. WALL
10
11
MAIN CLASSROOM (MC) PLAZA LEVEL (1st FLOOR)
28
1
10 LINE OF
PLAZA ABOVE 12
15
MAIN
LINE OF BRIDGE ABOVE
EXIT
19 ONLY
20
CONCRETE
EXIT ONLY
ENTRY ONLCYONCRETE
ENTRY 19
ONLY
20
11
CROSSHATCHED AREA INDICATES APPROXIMATE WORK LIMITS
LINE OF BRIDGE ABOVE
1.15' WIDE CONC. WALL
MUSIC (MU) PLAZA LEVEL BRIDGE
2' WIDE CONC.
CLASSROM
PLAZA CROSSHATCHED AREA INDICATES APPROXIMATE WORK
LIMITS
17
STUDENT CENTER (SC) LOWER LEVEL
VISITOR PARKING (LOT 22 PayStation)
G
LINE OF BRIDGE ABOVE
X
2
X X X
ENTRY
18 ONLY
STUDENT CENTER (SC)
WM 1st FLOOR
TRASH
G
LINE OF BRIDGE ABOVE
WM
WM
SM
SM
12" CONC. WALL
G
10 G G
33.38'
36.62'
SIGN
ASPH.
SIGN
G
W
R.O.W.
243.55' ASPH.
8" TREE
PROPOSED R/W
8" TREE
8" TREE
R.O.W.
G
G
EUCLID AVE.
NEW CONCRETE ROADWAY
U.G. TEL.
EUCLID AVE.
WARNER REF. USED
WARNER REF. USED
SITE LOGISTICS & STAGING PLAN - LOWER (STREET) LEVEL 2
SITE LOGISTICS & STAGING PLAN - PLAZA LEVEL 1
1 ISSUED FOR BIDDING 05-06-13
NO. REVISION DESCRIPTION DATE CONSULTANT: SEAL:
1" = 50'-0" A-011
1" = 50'-0" A-011
# SITE LOGISTICS CODED NOTES
# SITE LOGISTICS CODED NOTES
# SITE LOGISTICS CODED NOTES
1 PROPOSED STAGING AREA
2 CONTRACTOR RESPONSIBLE FOR ALL STREET/ LANE CLOSURE AND SIDEWALK CLOSURE PERMITS. COORD. w/ THE CITY AND CSU. CONTRACTOR TO ERECT BARRICADES AND DIRECTIONAL SIGNAGE AS REQ'D
3 MAINTAIN ADA ACCESS AT ALL TIMES
4 MAINTAIN DELIVERY DRIVE/ PARKING ACCESS
5 MAINTAIN ACCESS TO DELIVERY/ RECEIVING DOCK (TRASH & RECYABLES) COORD.
TEMP. CLOSURE WITH CSU FACILITIES/ OPERATIONS
6 MAINTAIN ACCESS AT ALL TIMES TO BUILDING, FIRE DEPT/ STAND PIPE CONNECTIONS
8 MAINTAIN DELIVERY/ RECEIVING DRIVE ACCESS
9 MAINTAIN ACCESS TO EXIST. FIRE HYDRANT
10 CONTRACTOR TO ERECT MOVABLE CONSTRUCTION BARRICADE AND PROVIDE DIRECTIONAL SIGNAGE AT ALL SIDEWALK CLOSURE POINTS
11 CONTRACTOR TO ERECT 6 FT HIGH CHAIN-LINK TEMPORARY FENCE WITH ACCESS GATES AT PERIMETER OF WORK LIMITS AND ALL STAGING AREAS.VERIFY FENCE LOCATIONS WITH OWNER'S REP. MAINTAIN ACCESS TO ITEMS NOTED, RELOCATE FENCE AS REQ'D TO MAINTAIN BUILDING ACCESS AND EMERGENCY EGRESS AT ALL TIMES
12 CONSTRUCTION WORK VEHICLE PARKING ON SITE IS LIMITED TO DESIGNATED STAGING AREAS. PARKING FOR CONSTRUCTION PERSONNEL IS ONLY AVAILABLE AT DESIGNATED ON-CAMPUS PAID PARKING FACILITIES OR ON-STREET METERED
PARKING.
14 PROPOSED DUMPSTER LOCATION
15 PLAZA LEVEL MAXIMUM LIVE LOAD IS LIMITED TO 100#/SF. VERIFY EQUIPMENT LOADING AND STAGING OF MATERIALS
16 INSTALL TEMPORARY SCAFFOLDING WALKWAY w/ OVERHEAD PROTECTION TO DELINEATE DESIGNATED EGRESS PATH. RELOCATE AS REQUIRED MAINTAINING MAXIMUM NUMBER OF EGRESS POINTS AT ALL TIMES DURING CONSTRUCTION ACTIVITIES.
17 (SC) RECEIVING DOCK
18 MAINTAIN GARAGE ACCESS AT ALL TIMES
19 MAINTAIN PARKING ENTRY/ EXIT ACCESS
20 11' MAX CLEAR HEIGHT BELOW PLAZA
21 MAINTAIN BUILDING ENTRY/ EXIT ACCESS AT ALL TIMES
22 MAINTAIN ACCESSIBLE WALKWAY
23 FIXED WOOD TRASH CONTAINER (TYP OF 2)TO BE REMOVED, INCLUDING ALL MOUNTING BRACKETS AND DISCARDED
24 STAINLESS STEEL LIBRARY BOOK DROP TO BE TEMP. RELOCATED AS DIRECTED BY CSU AND RE-INSTALLED UPON PROJECT COMPLETION
25 CLOTHING DONATION CONTAINERS (TYP OF 2) TO BE RELOCATED AND REPLACED UPON PROJECT COMPLETION
26 PICNIC TABLES (TYP OF 2) TO BE TEMP. RELOCATED AND RE-INSTALLED UPON PROJECT COMPLETION
29 TEMP RELOCATE AND RE-INSTALL CONC. BOLLARDS AS REQ'D FOR SCOPE OF WORK
30 FIXED GREEN CYLINDRICAL TRASH CONTAINERS TO BE REMOVED/ STORED AND RE-INSTALLED UPON PROJECT COMPLETION
31 RELOCATE ALL MOVABLE TRASH/ RECYCLE AND CIGARETTE DISPOSAL CONTAINERS
32 CONTRACTOR TO ERECT MOVABLE CONSTRUCTION BARRICADE AND PROVIDE DIRECTIONAL SIGNAGE (STUDENT CENTER (SC), RHODES TOWER (RT), LIBRARY & MAIN CLASSROOM (MC) DETOUR USE MUSIC BRIDGE)
33 CONTRACTOR TO ERECT MOVABLE CONSTRUCTION BARRICADE AND PROVIDE DIRECTIONAL SIGNAGE (RHODES WEST (RW) ACCESS ONLY)
34 RHODES WEST (RW) ACCESS TO BE MAINTAINED, COORD. TEMP CLOSURE WITH UNIVERSITY ACTIVITIES
36 AUTHORIZED VEHICLE PARKING ONLY CONSTRUCTION VEHICLE PARKING/ DELIVERY PARKING IS NOT ALLOWED OUTSIDE OF THE SPECIFIED PROJECT LIMITS SEE NOTE 12
GENERAL NOTES
1. ACCESSIBLE ENTRY INTO AND OUT OF RT & MC IS TO BE MAINTAINED AT ALL TIMES FOR THE DURATION OF CONSTRUCTION.
2. RT CONCRETE REPAIRS AT THE LOWER (STREET) LEVEL ABOVE EAST 21st AND EAST 22nd STREETS
IS TO BE LIMITED TO OFF HOURS, EVENING AND WEEKENDS IN ORDER TO LIMIT THE IMPACT OF STREET CLOSURES.
3. RT CONCRETE REPAIRS AT THE LOWER (STEET) LEVEL AT RT MAIN ENTRY ARE TO BE LIMITED TO OFF HOURS, EVENING AND WEEKENDS IN ORDER TO AVOID CLOSURE OF THE MAIN ENTRY. SEE CODED NOTE 16.
4. ALL WORK AT RT PLAZA LEVEL IS TO BE COMPLETED PRIOR TO COMMENCEMENT OF THE FALL 2013
SEMESTER. WORK TO BE SUBSTIANLY COMPLETE NO LATER THAN AUGUST 17, 2013, WITH PLAZA AND BUILDING ACCESS TO BE FULLY RESTORED.
5. A MINUMUM OF (1) ENTRY / EXIT AT THE MC PLAZA IS TO BE OPEN AT ALL TIMES FOR THE DURATION OF CONSTRUCTION. SEE CODED NOTE 28.
Cleveland State
University
Office of the University Architect
1802 East 25th Street, Plant Services Bldg. Cleveland, Ohio 44114
RT / MC PLAZA DECK WATERPROOFING AND CONCRETE REPAIRS
SITE LOGISTICS & STAGING PLAN
DRAWN BY BLDG PROJECT NO SHEET NUMBER TYP. REV.
13 INSTALL TEMP CONSTRUCTION BARRICADES AT ENTRY/ EXIT DOORS. PROVIDE
28 MC BUILDING ACCESS, MAINTAIN A MIN OF (1) ENTRY/ EXIT AT ALL TIMES. PROVIDE MOVABLE BARRICADES AND DIRECTIONAL SIGNAGE ON INTERIOR AND EXTERIOR.
D.Wilson
CW LF 1307A A-011
TS 1
DIRECTIONAL SIGNAGE
PROVIDE TEMP WALKING SURFACE AS REQ'D TO MAINTAIN EMERGENCY EGRESS
CAD FILE NO. ISSUE
SCALE: As indicated
- CD
0-GENERAL
Mailing Address
Cleveland State University
2121 Euclid Avenue, PS 235
Cleveland, OH 44115-2214
Campus Location
Plant Services Building
1802 East 25th Street, PS 235
Phone: 216-687-2500